1721 results found
    1. ADT 227, 227Ex, Dokumentierender Multifunktions-Prozesskalibrator

      ADT 227, 227Ex, Dokumentierender Multifunktions-Prozesskalibrator

      Simulates, measures, and outputs pressure, temperature, and electrical signals Documentable process calibrator (data logger) Built-in full HART communication (ADT227-HART) for 227Ex-Basic-HART communication Built-in barometer. Intrinsically safe models available (Ex) Large, user-friendly, smartphone-like touchscreen USB Type-C, Bluetooth communication IP67 protection class High-voltage measurement possible (300V AC) RMS voltage measurement function Dual-channel pressure module connections High static differential pressure measurement 0.002% of full scale

    2. ADT 761A, Automatischer Druck-Kalibrator

      ADT 761A, Automatischer Druck-Kalibrator

      Automatic and independent pressure generation and control up to 100 bar (1,500) psi Standard accuracy up to 0.01% VD (of the measuring range span) Two removable internal pressure modules for multi-range selection Control stability up to 0.003% VD Portable, designed for field and laboratory use Option to measure two external pressure modules Wi-Fi, LAN, Bluetooth, USB and Ethernet communication HART and Profibus communication Data storage and task documentation Patented electric pump technology with improved speed

    3. ADT 762, Automatischer Hydraulik-Druckkalibrator

      ADT 762, Automatischer Hydraulik-Druckkalibrator

      Automated pressure generation and control up to 1,035 bar (15,000 psi) Accuracy up to 0.01% of full scale Manual or automatic dual-range selection Control stability ≤ 0.005% of full scale Portable, designed for field and laboratory use Control via optional external pressure modules Supports two external pressure modules Communication via Wi-Fi, LAN, Bluetooth, USB, and Etherne Full HART communicator for field use HART and PROFIBUS communication Data storage and task documentation Patented electric pump technology

    4. ADT 762W, Automatischer Hydraulik-Druckkalibrator

      ADT 762W, Automatischer Hydraulik-Druckkalibrator

      Automated pressure generation and control up to 1,035 bar (15,000 psi) Accuracy up to 0.01% of full scale Manual or automatic dual-range selection Designed for use with water Automated fluid management Control stability ≤ 0.005% of full scale Designed for field and laboratory use Control via optional external pressure modules Supports two external pressure modules Communication via Wi-Fi, LAN, Bluetooth, USB, and Ethernet Full HART communicator for field use HART and PROFIBUS communication Data storage and task documentation Patented electric pump technology

    5. ADT 793, Druck-Controller

      ADT 793, Druck-Controller

      Maximum pressure control range up to 1000 bar (15,000 psi) Interchangeable pressure module Oil and water versions available Accuracy of 0.02%vE, 0.01%vE or 0.01%vM Two ranges from -1~200 bar to 0~1000 bar (-15~3,000 psi to 0~15,000 psi) Control stability 0.005%vE Ultra-fast pressure generation and control No external pressure source required Control via internal or external pressure modules Contamination Protection System (CPS) (ADT793 optional) LAN, USB, RS232 and Ethernet communication External reservoir support Easy maintenance Emulation mode

    6. ADT 875 - Serie, Trockenblock-Kalibratoren

      ADT 875 - Serie, Trockenblock-Kalibratoren

      Three models with a measuring range from -40°C to 660°C Portable, robust, and fast settling time Excellent performance in terms of stability and accuracy, with minimal loading effects Two-zone control Full HART field communication The process calibrator option (PC) offers a multi-channel display for a reference thermometer, RTDs and TCs, task documentation, and HART communication Color touchscreen display Select your own specific temperature measuring range Setpoint control optionally via an external reference temperature sensor.

    7. ADT 875-1210 & ADT 878-1210, Thermoelement-Kalibrieröfen

      ADT 875-1210 & ADT 878-1210, Thermoelement-Kalibrieröfen

      Temperature range from 100°C to 1210°C Two models to choose from: Reference (ADT 878) and Standard (ADT 875) Display accuracy: ± 1.5°C (ADT 878) Stability: ± 0.1°C 4 integrated measurement channels (PC option) The process calibrator option offers multi-channel readout for temperature controllers, switches, and transmitters, including task documentation and HART communication Portable, robust, and fast set-up time Self-calibration function (PC option) Multi-zone temperature control Internal and external sensor control (PC option) Interchangeable metal inserts Wi-Fi and Bluetooth enabled Color touchscreen display Patent-pending technology

    8. ADT 878, Referenz-Trockenblock-Kalibratore

      ADT 878, Referenz-Trockenblock-Kalibratore

      Three models with a measuring range of -40℃ to 700℃ Reference-level performance in terms of accuracy, stability, and homogeneity Fast temperature rise Dual-channel display measures RTDs and TCs Task documentation Full HART communicator (PC option) Optional external temperature control Wi-Fi and Bluetooth enabled Color touchscreen display Quick-push ports (PC option) Setpoint monitoring by reference Self-calibration function Optional TPW kit for integrated automatic TPW implementation (ADT878-160 only) Built-in automatic cooling function (ADT878-700 only)