
Camille Bauer Metrawatt AG
About us
As a leading supplier of high-quality measurement technology, we have been making our customers’ electrical engineering processes more efficient and safer for generations.
With our measurement technology and complete solutions, we monitor all invisible variables of electrical energy and distribution processes, ensure a stable energy supply and prevent damage to people and materials.
Products

Mastering the energy transition - wireless recording of electrical parameters
As the energy transition has to be mastered to a large extent with existing systems, there is a need for technologies that can be retrofitted into systems as efficiently as possible. To achieve this, Camille Bauer's wireless technology was brought into the energy transition. The standard measuring devices of the SINEAX® AMx000, LINAX® PQx000, SINEAX® DM5000 and CENTRAX® CUx000 series are equipped with a data concentrator in addition to their function as a measuring instrument. This data concentrator connects almost automatically to the wireless sensors of the PME series and maps the low-voltage system at distribution level. The standard measuring devices can be mixed with their data concentrators as required and according to the use case. Thanks to the open connectivity, many connections to higher-level or parallel systems are possible (e.g. SCADA, BMS, ISO5000x energy management, energy monitoring, smart grid applications, power quality and energy monitoring, etc.). PME sensors of 25 x 4PN or 33 x 3P are possible per data concentrator. Up to 4 data concentrators in close proximity per system, i.e. up to 100 (4PN) / 132 (3P) outlets can be seamlessly recorded on the basis of Bluetooth technology.

For security of supply and energy efficiency in the low-voltage grid
Feeder focused and synchronized measurements in the low-voltage grid prevent faults and outages. Multichannel power quality and load flow for network level 7 (low voltage). Two innovative variants support this: The LINAX® PQ5000 MOBCL portable load flow meter for the simultaneous & feeder focused recording of all load profiles, including recording the voltage quality. The portable power quality and load flow measuring device LINAX® PQ5000 MultiPQ for simultaneous & feeder focused recording of all load profiles, including comprehensive power quality analysis per feeder Your benefit: - Comprehensive analysis of the power quality for all feeders (MultiPQ only) - Time-synchronous recording and analysis of up to 9 feeders simultaneously - Only one measuring device instead of nine expensive individual devices saves money - Only one measuring device reduces the installation effort enormously and saves time - Only one evaluation instead of nine individual reports increases efficiency

Intelligent measurement and control system for PV systems
The structure is based on a decentralized and self-sufficient system with so-called "SmartGridBoxes" from Camille Bauer. The individual states of the distribution boxes (low voltage) are recorded dynamically and in real time. The measured values are transmitted to a decentralized leader via LTE router, IoT gateway or broadband. From there, the status is compared with the target values. Depending on the difference, the inverters receive a control command via a controller for green power generation systems so that PV systems only feed into the grid in stages when this is actually beneficial to the grid.

Interference-free thanks to optimum voltage quality
Camille Bauer now offers a comprehensive assessment of the compatibility between the electricity fed into a grid and the consumers connected to this grid. Distribution system operators assess grid perturbations in accordance with technical regulations, e.g. DACHCZ, before new customer systems are connected or installation changes are made. Until now, there has been little or no possibility to check the grid feedback of customer systems during operation using measurement technology, e.g. according to the criteria of DACHCZ Ed. 3. Functions - Metrological verification of compliance with harmonic limits in report form - Identification of customer systems with impermissibly high grid perturbations - Recognition of existing interactions between the grid and the customer system (e.g. compensation effects) Benefit - Avoidance of investments in unnecessary mitigation measures - Consideration of faults in the neutral conductor for customer systems remote from the transformer - More reliable operation of existing and future grids with more efficient use of the grid infrastructure - Increased security of supply - No in-depth knowledge required to evaluate the harmonic contribution - Unknown system parameters can be replaced by standard values 4 functions in one device 1. Fault recorder using event recording in accordance with IEC 61000-4-30 Ed. 3, Class A 2. Conformity assessment of the power quality (e.g. according to EN 50160, IEEE 519, GB/T ...) 3. NEW: Evaluation of harmonic emissions (e.g. according to DACHCZ Ed. 3, IEEE 519, DTR, IEEE 1547, GB/T...) 4. Recording of load profiles, short-term load peaks and meter values

Specialist seminar in accordance with NIV for holders of an installation permit
The NIV specialist seminars offer you the opportunity to keep your knowledge of electrical safety, standards and regulations up to date. We have interesting topics ready for you. The following topics are covered in the seminars: - Stray currents in agricultural operations - Emergency power supply - Photovoltaic system: Checking during commissioning and performance monitoring - Voltage quality in PV systems - Checking AC electric charging stations - Device testing for the practitioner (live check)